High temperature. Impact-resistant, impact-resistant fixed in packages weighing equipment
■ Key performance indicators
※ Accuracy class: 0.5% F · S
※ Weighing Scale (t): 40,60,80,100
※ Safe Overload: 200%
※ Environment condition Power supply: Power supply AC220 +22 V/AC220-33V, 50 ± 1Hz
Temperature meter -10 ~ 50 ℃, -40 ~ 500 ℃ sensor
Humidity 40 ℃ (2 - ~ 90)% RH
In packages weighing components Dimensions
Weighing Scale (t) | A | B | B1 | C | C1 |
40、60 | 360 | 190 | 90 | 240 | 190 |
80、100 | 400 | 200 | 100 | 260 | 210 |
■ System Block Diagram
■ Key Features
※ According ladle scales high temperature, strong impact with features specially developed and produced.
※ sensor uses Japanese origin republican companies and high-temperature high-temperature compensated strain gages, aging, testing, production process.
■ Outline and installation diagram